IFC - International Fumigation Company provides disinfection services for silos, tanks and bins at factories. We also specialize in providing disinfection services for warehouses, agricultural products and factories. To help you better understand the silo sterilization process, we will share with you 5 steps of the disinfection process.

1. Learn about Silo

Silo is a material storage tank system used to deal with ground pressure and maintain material flow in the production process. However, how to preserve the quantity of goods and materials in the silo without loss due to the invasion of insects?

 

IFC's company will help you solve all these problems, with a team of professional and experienced technical staff.

2. 5-Step Silo Sterilization Process

2.1 Surveying and measuring

During the survey of the area around the Silo to carry out disinfection, we will conduct a check of factors such as the surrounding area, including residential areas, main and auxiliary ventilation, fan system Air island of the silo and the tightness of the silo (silo is made of steel or cement).

 

We will also conduct cargo surveys to determine the type, weight, volume, temperature and humidity of the cargo, as well as the temperature and humidity of the air. At the same time, we will conduct pest surveys to identify major and subspecies, as well as reproductive stages.

 

Finally, we will measure the size of the Silo or based on the number of tons of goods provided by the factory to calculate the dose of medicine used in the sterilization process.

2.2 Preparatory work

To perform silo sterilization, you need to prepare:

 

Personnel: Determine the required number of employees.

 

Materials and equipment:

Rulers, hats, gloves, masks, respirators, goggles, toxic gas detection pumps, warning signs, ladders, flashlights, kraft paper, adhesive tapes, medical tools,...

 

Operation:

  • Seal the system, ventilation doors, exhaust fans, lids, openings of the silo.
  • For silo with air island system, connect the common air island system and place the pipeline from top to bottom according to the wind direction.
  • For silos without air island system, the factory's support is needed to create a pipeline to attach the air island to the bottom of the silo.
  • Pressure test:
  • Place the pressure gauge in the marked position.
  • Check the manometer before use.
  • Connect the air intake and seal.
  • Create negative pressure inside the silo with an air extractor.
  • Reduce pressure from 500 Pascals to 250 Pascals for about 15 minutes to test the tightness of the Silo.

2.3 Disinfection operation

The captain's notice to the manager of the Silo disinfection area to ask the people to leave that area. After that, the team carried out materials and equipment into the silo and did a general inspection of the silo.

 

They place and post warning signs and ensure adequate availability of medication, parachute cords, cloth bags, silos sealing materials, air ducts, chicken intestines and sealed pressure test doors. The team leader gathers and re-checks the workers and reports on the preparation situation before ordering the medicine.

 

They will then place the medication for a maximum of 15 minutes. The pills must be spaced and not stacked on top of each other, not piled up, and not smoke or eat junk food while taking the pills. When ordering drugs, captains and workers must wear masks, gloves and protective shoes. They also had to hang the cloth bag containing the medicine on the rope even though it was strung on the silo.

2.4 Realm

The duties of the police officer include:

 

  • Check warning signs.
  • Use a measuring device to check for drug leaks.
  • Troubleshoot if any.
  • Check drug levels at the following times:

1st time: 10 hours after placing the medicine.

2nd time: 12 hours after placing the medicine.

3rd time: 14 hours after placing the medicine.

  • Performing the test must have at least 2 people and keep a minimum distance of 5m between them.
  • Record all test data in the watchdog, including test results of concentration, time, incident (if any) and how to handle the problem.
  • Prevent unauthorized persons from entering the silo disinfection area during the incubation period.
  • Wear a protective mask when refueling is required.

2.5 Ventilation and acceptance

To disinfect silos with phosphide, the drug should be incubated for at least 72 hours. Then, perform silo ventilation according to the following steps:

  • Open the silo door seal and all doors for ventilation.
  • Peel off the glued krapf sheets and remove the original sealing items.
  • Clean up residues of medicine, do not scatter and spray disinfectant around the silo.
  • Acceptance of silos by taking samples of sterilized goods (sampling method depends on the factory).
  • Prepare acceptance test report according to the company's template.

 

 

 

This is a 5 step process to disinfect silos. If you have a need, please contact the International Fumigation Company IFC. Thank you for your trust.

 

Contact Info

International Fumigation Company (IFC)

Phone: 0938. 929. 101

Email: ifc@khutrungquocte.com

0.0           0 reviews
0% | 0
0% | 0
0% | 0
0% | 0
0% | 0
Did you know the 5-step process of silo sterilization?

Cám ơn bạn đã gửi đánh giá cho sản phẩm này! Đánh giá của bạn sẻ giúp chúng tôi cải thiện chất lượng dịch vụ hơn nữa.

  • Lọc theo:
  • Tất cả
  • 1
  • 2
  • 3
  • 4
  • 5
Chia sẻ
Database Error

Công Ty Truyền Thông Và Quảng Cáo Siêu kinh doanh

A Database Error Occurred

Error Number: 1055

Expression #22 of SELECT list is not in GROUP BY clause and contains nonaggregated column 'khutrungqu_db.lg.title' which is not functionally dependent on columns in GROUP BY clause; this is incompatible with sql_mode=only_full_group_by

SELECT `cle_post`.*, `lg`.`title`, `lg`.`content`, `lg`.`excerpt`, `lg`.`language` FROM `cle_post` JOIN `cle_relationships` as `r` ON `r`.`object_id` = `cle_post`.`id` JOIN `cle_relationships` as `r2` ON `r2`.`object_id` = 163 AND `r`.`category_id` = `r2`.`category_id` JOIN `cle_language` as `lg` ON `lg`.`object_id` = `cle_post`.`id` WHERE `public` = 1 AND `trash` = 0 AND `post_type` = 'post' AND `cle_post`.`id` <> '163' AND `r2`.`object_type` = 'post' AND `lg`.`language` = 'en' AND `lg`.`object_type` = 'post' GROUP BY `r`.`object_id` ORDER BY `order`, `created` desc LIMIT 6

Filename: /home/khutrungqu/domains/khutrungquocte.com/public_html/core/MY_Model.php

Line Number: 199